Allied Telesis SwitchBlade x8106 User Manual

Page 185

Advertising
background image

SwitchBlade x8106 Chassis Switch Installation Guide

185

2. Connect the other end of the cable to an RS-232 port on a terminal or

personal computer with a terminal emulation program.

3. Configure the VT-100 terminal or terminal emulation program as

follows:

Baud rate: 115,200 bps

Data bits: 8

Parity: None

Stop bits: 1

Flow controller: None

Note

The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.

4. Press Enter. You are prompted for a user name and password.

5. Enter the default user name and password. They are “manager” and

“friend” (without the quotes), respectively

Note

User names and passwords are case sensitive.

The local management session starts and the command line interface
(CLI) prompt is displayed.

Entering the

AlliedWare Plus

Operating System

Commands

To confirm the operations of the chassis with the commands in the
AlliedWare Plus Operating System, perform the following procedure:

1. Enter the SHOW VERSION command in the User Exec or Privileged

Exec mode to display the software version number of the AlliedWare
Plus Operating System on the controller card, as shown in Figure 135
on page 186.