Defining RMON Alarms

The RMON Alarm Page contains fields for setting network alarms. Network alarms occur when a network
problem, or event, is detected. Rising and falling thresholds generate events.

To set RMON alarms:

1.

Click Statistics > RMON Alarm. The RMON Alarm Page opens:

Figure 161:RMON Alarm Page

The RMON Alarm Page contains the following fields:

Alarm Entry — Indicates a specific alarm.

Counter Name — Displays the selected MIB variable.

Interface — Displays interface for which RMON statistics are displayed. The possible field values are:

Port — Displays the RMON statistics for the selected port.

Trunk — Displays the RMON statistics for the selected trunk.

Counter Value — Displays the selected MIB variable value.

Sample Type — Defines the sampling method for the selected variable and comparing the value against the

thresholds. The possible field values are:

Delta — Subtracts the last sampled value from the current value. The difference in the values is

compared to the threshold.