Allied Telesis AT-MCF2000M User Manual

Page 25

Advertising
background image

AT-MCF2000M Management Module Installation Guide

25

An example of a stack with four media converter chassis is
illustrated in Figure 3.

Figure 3. Example Stack of Four Media Converter Chassis

The Stack port on the management module and the
stacking module use standard straight-through or crossover
TIA/EIA 568-B-compliant Enhanced Category 5 (Cat 5e)
shielded or unshielded cabling with 100 ohm impedance.
The maximum length of a cable is 100 meters, as shown in
Figure 4. This makes it possible to create a stack of devices
in different racks or even different wiring closets.

Figure 4. Maximum Stacking Cable Length

To manage a stack, you must start your local and remote
management sessions on the management module. For
local management, you connect a terminal or a personal
computer with a terminal emulation program to the RS-232
Terminal port on the management module. For remote
management, such as with the Telnet application protocol,
you assign the management module an IP configuration
and access the module from your remote workstation using
the module’s IP address.

Unit with the

AT-MCF2000M

Management

Module

Units with the

AT-MCF2000S

Stacking

Module

100 meters

maximum