background image

Chapter 11: Event Log and Syslog Servers

132

Section II: Advanced Operations

For example, the setting of DEFAULT assigns all port mirroring events
a code of 22 and all encryption key events a code of 4.

Your other option is to assign all events from a switch the same
numerical code using one of the following facility level settings:

ˆ

LOCAL1

ˆ

LOCAL2

ˆ

LOCAL3

ˆ

LOCAL4

ˆ

LOCAL5

Table 4. Applicable RFC 3164 Numerical Code and AT-S62 Module

Mappings

Numerical

Code

RFC 3164 Facility

AT-S62 Module

4

Security and
authorization
messages

Security modules:
- PSEC
- PACCESS
- ENCO
- PKI
- SSH
- SSL
- MGMTACL
- DOS

Authentication modules:
- SYSTEM
- RADIUS
- TACACS+

9

Clock daemon

Time- based modules:
- TIME (system time and SNTP)
- RTC

22

Local use 6

Physical interface and data link
modules:
- PCFG
- PMIRR
- PTRUNK
- STP
- VLAN

23

Local use 7

SYSTEM events related to major
exceptions.

16

Local use 0

All other modules and events.