Allied Telesis AT-S62 User Manual
Page 132
Chapter 11: Event Log and Syslog Servers
132
Section II: Advanced Operations
For example, the setting of DEFAULT assigns all port mirroring events
a code of 22 and all encryption key events a code of 4.
Your other option is to assign all events from a switch the same
numerical code using one of the following facility level settings:
LOCAL1
LOCAL2
LOCAL3
LOCAL4
LOCAL5
Table 4. Applicable RFC 3164 Numerical Code and AT-S62 Module
Mappings
Numerical
Code
RFC 3164 Facility
AT-S62 Module
4
Security and
authorization
messages
Security modules:
- PSEC
- PACCESS
- ENCO
- PKI
- SSH
- SSL
- MGMTACL
- DOS
Authentication modules:
- SYSTEM
- RADIUS
- TACACS+
9
Clock daemon
Time- based modules:
- TIME (system time and SNTP)
- RTC
22
Local use 6
Physical interface and data link
modules:
- PCFG
- PMIRR
- PTRUNK
- STP
- VLAN
23
Local use 7
SYSTEM events related to major
exceptions.
16
Local use 0
All other modules and events.