Allied Telesis AT-MC103ST/FSx User Manual

Page 34

Advertising
background image

Technical Specifications

22

Table 9 Fiber Optic Loss Specifications (Benchmarks)

AT-MC103SC/FS3
and
AT-MC103ST/FS3

9/125 SMF

33.00 dB

35.00 dB

15 km
(9.4 mi)

75 km
(46.5 mi)

AT-MC103SC/FS4
and
AT-MC103ST/FS4

9/125 SMF

34.00 dB

35.50 dB

40 km
(24.8 mi)

100 km
(62 mi)

1. MMF = Multimode Fiber / SMF = Single-mode Fiber

2. The recommended minimum range is stated in all cases where the maximum transmitter output power exceeds

the receivers saturation level. This is to prevent blinding or burning out of the optical receiver on the far-end-node.

Fiber Type

1

1. MMF = Multimode Fiber / SMF = Single-mode Fiber

Fiber Optic
Diameter
(microns)

Optical
Wavelength

Typical
Loss
Factor
(dB/km)

Worst Case
Loss Factor
(dB/km)

Bandwidt
h (Mhz-
km)

MMF

50/125

850 nm

3.00

3.50

400

50/125

1310 nm

1.00

1.50

400

62.5/125

850 nm

3.00

3.75

200

62.5/125

1310 nm

1.00

1.50

500

100/140

850 nm

4.00

4.00

100

SMF

9/125

1310 nm

0.40

1.00

N/A

9/125

1550 nm

0.30

0.75

N/A

Table 8 Fiber Optic Datalink

(Continued)

Model

Fiber
Type

1

Minimum
Power /
Link
Budget

Average
Signal
Loss

Minimum
Distance
Spec.

2

Maximum
Distance
Spec.

Advertising