Head2 - cable specifications, Cable specifications – Allied Telesis AT-PBC18 User Manual

Page 85

Advertising
background image

PowerBlade PBC18 Installation Guide

85

Cable

Specifications

Table 30 lists the cable specifications for the 10/100Base-TX twisted pair
port for all AT-PB200 and AT-PB202/x Series models.

Table 30 10/100Base-TX Twisted Pair Cabling Specifications

Table 31 lists the cable specifications for the 100Base-FX fiber optic port
for all AT-PB200 and AT-PB202/x Series models when operating in full-
duplex mode.

Table 31 100Base-FX Cabling Specifications (Full-duplex)

Operating
Mode

Cable

Maximum
Distance

10Base-T

Shielded or unshielded twisted
pair Category 3 or better

100 m (328 ft)

100Base-TX

Shielded or unshielded twisted
pair Category 5 or better

100 m (328 ft)

Model

Cable

Maximum
Distance

Maximum
Allowable Loss
Budget

AT-PB201
AT-PB202
AT-PB204
AT-PB205
AT-PB206
AT-PB207

50/125 or
62.5/125 µm
multimode

2 km (1.2 mi)

13 dB at 1310 nm

AT-PB202/1

9/125 µm
single-mode

15 km (9.3 mi)

16 dB at 1310 nm

AT-PB202/2

9/125 µm
single-mode

40 km (24.8 mi)

30 dB at 1310 nm

AT-PB202/3

9/125 µm
single-mode

70 km (43.4 mi)

37 dB at 1310 nm

AT-PB202/4

9/125 µm
single-mode

1

1. The cable can be non-dispersion-shifted, dispersion-shifted, or non-zero dispersion-shifted single-mode fiber optic cable.

100 km (62 mi)

37 dB at 1310 nm

Advertising