Troubleshooting, Technical specifications – Allied Telesis AT-MC103LH User Manual

Page 13

Advertising
background image

Installation Guide

9

Troubleshooting

To troubleshoot your media converter, perform the following:

1. Set the unit in the Link Test mode.

2. End stations used with the media converter must operate in the same

duplex mode (either both full-duplex or both half-duplex).

3. Verify that the twisted pair cable is Category 5.

4. Verify that proper fiber cable is being used: multimode for the

AT-MC101XL and AT-MC102XL, and single mode for the AT-MC103XL
and AT-MC103LH. Refer to Table 3 on page 10 for cable specifications

5. Verify that the near end node transmitter (TX) is connected to the far end

node receiver (RX) and vice versa on the fiber segment.

Technical Specifications

Table 2 lists the media converter technical specifications.

Table 2 Media Converter Technical Specifications

Specifications

Dimensions

4.125 in W x 3.75 in D x 1.0 in H
(10.5 cm W x 9.5 cm D x 2.5 cm H)

Max. Operating temperature

0° C to 40° C (32° F to 104° F)

Max. Storage temperature

-20

o

C to 80

o

C (-4° F to 176° F)

Operating altitude

up to 10,000 ft (3,048 m)

Humidity 5%

to

80%

(noncondensing)

EMI/RFI

meets FCC Class A, EN55022 Class A

Safety

EN60950, UL 1950, CSA 950
EN60825

Immunity

EN50082-1 Immunity Standard

Power
Input supply voltage
Max. current
Power consumption

12 V DC +/-5%
500 mA
6W