Recommended cables and cable specifications – Allied Telesis AT-MC103LH User Manual

Page 14

Advertising
background image

10

Recommended Cables and Cable Specifications

Table 3 lists the IEEE 802.3u cabling specifications for the media converters.
Refer to Table 3 for cabling recommendations.

Note 1. Single-mode fiber transmitter is rated as a Class 1 laser.
Note 2. Each Media Converter used inline within a single collision domain will reduce the overall segment length by

40 m (131.24 ft) of fiber.

Note 3. Applies only to the AT-MC103XL, Single Mode Fiber Optic Transmitter/Receiver.
Note 4. Applies only to the AT-MC103LH, Single Mode Fiber Optic Transmitter/Receiver.

Table 3 IEEE 802.3u Cabling Specifications for Media Converters

100Base-FX

100Base-TX

Media

1300 nm multimode fiber, 50/125 micron
1300 nm multimode fiber, 62.5/125 micron
1300 nm single-mode fiber, 9/125 micron
(see Note 1)

Unshielded/
Shielded Twisted
Pair Category 5 only

Topology

Star, Tree

Star, Tree

External
Devices

Network Adapter Card, Repeater, Switch, Router, or
Bridge

Network Adapter
Card, Repeater,
Switch, or Router

Maximum
Segment
Length

100BaseFX Full-Duplex operation:
Multimode fiber (MMF), 2 km (1.2 mi)
Single mode fiber (SMF), 15 km (9.32 mi) (XL
model only, see Note 3.)
Single mode fiber (SMF), 40km (24.9 mi) (LH model
only, see Note 4.)
100BaseFX Half-Duplex operation:
The total distance of all fiber runs cannot exceed
the following limits: (see Note 2)
with one Media Converter inline:
Switch to Switch = 372 m (1221 ft)
Work Station to Switch = 372 m (1221 ft)
Switch to Class II Repeater = 185 m (607 ft)
Switch to Class I Repeater = 137 m (450 ft)
with two Media Converters inline:
Switch to Switch = 332 m (1089 ft)
Work Station to Switch = 332 m (1089 ft)
Switch to Class II Repeater =145 m (476 ft)
Switch to Class I Repeater = 97 m (318 ft)

328 ft (100 m)