Table 4, Nd table 5 li – Allied Telesis AT-MC103ST/FS3, FS4 User Manual

Page 19

Advertising
background image

AT-MC100 Series Installation Guide

9

Table 4 100Base-FX Fiber Optic Port Specifications (Full-duplex)

Table 5 100Base-FX Fiber Optic Port (Half-duplex)

1

1.

The total distance of all fiber lengths cannot exceed the limits stated in the table. Each media converter used inline
within a single collision domain reduces the overall segment length by 40 meters (131 feet).

Model

Type of Fiber Optic
Cable

Maximum
Distance

Maximum Allowable
Loss Budget

AT-MC101XL

50/125 or 62.5/125
micron multimode

2 km (1.2 mi)

13 dB at 1310 nm

AT-MC102XL

50/125 or 62.5/125
micron multimode

2 km (1.2 mi)

13 dB at 1310 nm

AT-MC103XL

9/125 micron
single-mode

15 km (9.3 mi)

16 dB at 1310 nm

AT-MC103LH

9/125 micron
single-mode

40 km (24.8 mi)

16 dB at 1310 nm

AT-MC103SC/FS3

9/125 micron
single-mode

75 km (46.5 mi)

1

1. The media converter has a minimum operating distance of 15 km (9.4 mi). This is to prevent blinding or

burning out of the optical receiver on the far-end node.

33 dB at 1310 nm

AT-MC103ST/FS3

9/125 micron
single-mode

75 km (46.5 mi)

1

33 dB at 1310 nm

AT-MC103SC/FS4

9/125 micron
single-mode

100 km (62 mi)

2

2. The media converter has a minimum operating distance of 40 km (24.8 mi). This is to prevent blinding or

burning out of the optical receiver on the far-end node.

34 dB at 1550 nm

AT-MC103ST/FS4

9/125 micron
single-mode

100 km (62 mi)

2

34 dB at 1550 nm

Number of Media Converters

Connected Devices

Maximum Distance

One Media Converter Inline

Switch to Switch

372 m (1,221 ft)

Workstation to Switch

372 m (1,221 ft)

Switch to Class I Repeater

137 m (450 ft)

Switch to Class II Repeater

185 m (607 ft)

Two Media Converters Inline

Switch to Switch

332 m (1,089 ft)

Workstation to Switch

332 m (1,089 ft)

Switch to Class I Repeater

97 m (318 ft)

Switch to Class II Repeater

145 m (476 ft)

Advertising