Blodgett BTT-16G User Manual

Page 5

Advertising
background image

5


1.0 SERVICE CONNECTIONS (Continued)

Installation must conform with local codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1
, as applicable.

1. The appliance and its individual shut off valve must be disconnected from the gas

supply piping system during any pressure testing of that system at pressures in
excess of ½ psi (3.5 kPa).


2. The appliance must be isolated from the gas supply piping system by closing its

individual manual shut off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than ½ psi (3.5 kPa).


Electrical grounding must be provided in accordance with local codes, or in the absence
of local codes, with the National Electric Code ANS1/NFPA 70, or the Canadian
Electrical Code, CSA C22.2, as applicable.

Ventilation must be provided in accordance with local codes, or in the absence of local
codes, with ANSI/SFPA 96 Standard for Ventilation and Fire Protection of Commercial
cooker Operations.

WARNING: Electrical grounding instructions - units equipped with a
three-prong (grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding prong
from this plug. (120 volt units only).

Advertising