Installation, Oven description and specifications – Blodgett CTBR User Manual

Page 4

Advertising
background image

2

Installation

Oven Description and Specifications

ELECTRICaL RaTInGS- CTB & CTBR

VOLTaGE

kW

PhaSE

Max LOad (aMPS)

ELECTRICaL COnnECTIOn

aWG*

L1

L2

L3

N

60 hZ

208

5.6

1

27

27

8

5.6

3

24

12

15

10

6.8

1

33

33

6

6.8

3

20

18

19

10

8.0

1

35

35

6

8.0

3

22

20

21

10

220-240

5.6

1

24

24

8

5.6

3

21

11

14

10

6.8

1

28

28

6

6.8

3

18

16

17

10

8.0

1

32

32

6

8.0

3

20

18

19

10

50 hZ

220-240

5.6

1

24

24

Size per local codes

6.8

1

28

28

8.0

1

35

35

240/415

5.6

3 WYE

11

0

9

3

Size per local codes

6.8

3 WYE

11

9

9

8.0

3 WYE

13

11

11

2

230/400

5.6

3 WYE

11

0

10

1

Size per local codes

6.8

3 WYE

11

9

9

8.0

3 WYE

13

11

11

2

* Electric connection wiring is sized for 90ºC copper wire at 125% of rated input.

NOTE: Double units can have phase loads partially equalized by matching lines during hook-up. Otherwise, CTB-Double

or CTBR-Double load ratings are twice the above data.

Cooking in a convection oven differs from cooking in a

conventional deck or range oven since heated air is con-

stantly recirculated over the product by a fan in an en-

closed chamber. The moving air continually strips away

the layer of cool air surrounding the product, quickly al-

lowing the heat to penetrate. The result is a high qual-

ity product, cooked at a lower temperature in a shorter

amount of time.

Blodgett convection ovens represent the latest advance-

ment in energy efficiency, reliability, and ease of opera-

tion. Heat normally lost, is recirculated within the cooking

chamber before being vented from the oven: resulting in

substantial reductions in energy consumption and en-

hanced oven performance.