OM-KPT/KLT-DS 11

Maintenance

NOTICE: Contact an authorized representative when repairs are required.

Periodic Maintenance

A Service Log is provided at the back of this manual with the warranty information.

Each time maintenance is performed on your kettle, enter the date on which the work

was done, what was done, and who did it. Keep this manual on file and available for

operators to use.

Periodic inspection will minimize equipment down time and increase the efficiency of

operation. The following points should be checked:

1. Once a day, with pressure in the jacket, check the operation of the safety valve.

Lift the lever of the safety valve until steam is released. Then release the lever

and let the valve snap shut. If the lever does not activate, or there is no evidence

of discharge, or the valve leaks, immediately discontinue use of the kettle and

contact a qualified service representative.

2. At least once every 90 days, inspect fittings and valves for signs of damage or

wear. Regularly examine trunnion packings and valve seats for wear, and replace

them when necessary.

NOTE: Service performed by other than factory authorized personnel will void all

warranties.

3. Lubricate trunnions and gears with a good grade of high temperature grease.

Grease trunnions at least once every 60 days, and grease gears when inspection

shows that they are dry.

4. If the kettle cover has an actuator, lubricate it every 90 days.

NOTE: Use only Calcium Complex Nr. 2 Grease.

WARNING

WHEN TESTING, AVOID ANY EXPOSURE

TO THE STEAM BLOWING OUT OF THE

SAFETY VALVE. DIRECT CONTACT

COULD RESULT IN SEVERE BURNS.

CAUTION

USE OF ANY REPLACEMENT PARTS

OTHER THAN THOSE SUPPLIED BY THE

MANUFACTURER OR AN AUTHORIZED

SUPPLIER WILL VOID ALL WARRANTIES AND

COULD INJURE THE OPERATOR OR DAMAGE

THE EQUIPMENT.