Pecifications – Swiftech H20 120 User Manual

Page 16

Advertising
background image

Tube insertion

TIP!

Rubbing the extremity of the tube with a little bit of liquid soap will greatly facilitate insertion of the tube into the quick-connect fitting.


Insert the tube into the quick-connect fitting. The tube will go in freely for the first ¼” and you will then feel a resistance: this is the O-ring inside of
the fitting. Push through the O-ring by twisting the tube back-and-forth for another ½” until the tube reaches the tube-stop at the bottom of the fitting.

Figure 7

Figure 8

Tube removal


Firmly grip the tube in the cradle formed by three fingers, and push
against the blue collet with thumb and index fingers. This will
disengage the tube from the fitting. Correct position of the hand
and fingers is shown in Figure 6.

Figure 9

4. Specifications

Radiator Assembly Dimensions - Part # MCR120-FB

Thickness Height

Core width

Inlet Outlet tube size

0.98"

(25mm)

5.9"

(157mm)

5.00"

(133mm)

1/2" (tube OD) quick connect adapters included

Fan Specifications - Part # WFB1212M

Voltage

(V)

Current

(mA)

Speed
(RPM)

Volume

(CFM)

Static pressure

(InH20)

Sound Noise

(dbA)

7.0-13.8 .20

2100

72.4

.134

34

Advertising