4 MCRES-1000P

ASSEMBLY INSTALLATION

Introduction
The radiator inlet and outlet spigots must be oriented upwards during the filling procedure
. If you are using the Radbox, and already fastened
the radiator/fan/Radbox housing to the Radbox base plate, go ahead and dismount the assembly and let the radiator/fan/housing assembly hang down
over your bench table as shown in the picture paragraph B step1. Generally speaking proceed deliberately and frequently check your work. Rushing

this procedure is not recommended

.

Two methods can be used to fill-up the reservoir:

Preferred: whenever possible, the reservoir should be filled before placing it in the CD-Rom bay. This is the easiest and safest
method, described in paragraph A below.
Alternate: If your chassis configuration necessitates that the reservoir be installed in the CD-Rom bay prior to filling, please refer
to paragraph B “Alternate Filling Method”.

‰ Preparing the HydrX coolant

Before you begin filling up your circuit, you need to prepare the coolant. Your kit comes with a 2 Oz (60ml) bottle of Swiftech’s specially formulated
HydrX

™ concentrated coolant. The product should be mixed with distilled or demineralized water only. Simply empty the concentrated coolant into a 33

fl oz (1 liter) plastic bottle, and complete filling with distilled water. Your coolant is now ready.

‰ A. First time installation and preferred filling procedure

Step 1. Cutting the tubes to length: position the MCRES-1000 in the
desired CD-Rom drive bay, and cut sufficient length of tubing to allow the
assembly to slide back for periodic maintenance purposes.

Step 2. Connect the discharge tube to the pump (coming from either
CPU inlet, or radiator for example), and the return line to the reservoir
inlet barb. Secure the tubes with the provided hose clamps.

Step 3. Rest the MCRES-1000P assembly on a paper towel or cloth on
top of the computer. Using a household funnel, slowly fill-up the reservoir
with cooling fluid until the fluid reaches the appropriate level --

ÆÆ

3. Appropriate level: up to the vent hole.