inside your chassis.

From a performance standpoint there is very little performance to be gained from strictly controlling the component sequence: the
maximum delta T (difference in temperature) between any two points of the liquid cooling circuit does not exceed 1ºC. Whenever
possible, performance oriented users will typically want to route the radiator discharge(s) tube(s) to the inlet of the CPU cooler, since
the fluid exiting the radiators is always the coolest.

Devices:

(1) CPU cooler + (1) VGA Cooler + (1) chipset Cooler + (1) Radiator + Pump-reservoir assembly

Connect:

Reservoir discharge to pump inlet – MANDATORY!

Pump discharge to chipset cooler inlet

Chipset cooler discharge to VGA cooler inlet

VGA cooler discharge to radiator inlet

Radiator discharge to CPU cooler inlet

CPU cooler discharge to reservoir inlet

Devices:

(1) CPU cooler + (2) VGA Coolers + (1) chipset Cooler + (1) Radiator + Pump-reservoir assembly

Connect:

Reservoir discharge to pump inlet – MANDATORY!

Pump discharge to chipset cooler inlet

Chipset cooler discharge to VGA (1) cooler inlet

VGA (1) cooler discharge to VGA (2) cooler inlet

VGA (2) cooler discharge to radiator inlet

Radiator discharge to CPU cooler inlet

CPU cooler discharge to reservoir inlet

Devices:

Dual CPU cooler and VGA cooler (SLI) configurations

Connect:

CPU coolers in series: CPU cooler (1) discharge to CPU cooler (2) inlet

VGA coolers in series: VGA cooler (1) discharge to VGA cooler (2) inlet

Devices:

Dual Radiators: A second radiator can be added anywhere in the loop in series with the other components,
for example

Connect

Reservoir discharge to pump inlet – MANDATORY!

Pump discharge to radiator (1) inlet

Radiator (1) discharge to VGA cooler inlet

VGA Cooler discharge to chipset cooler inlet

Chipset cooler discharge to radiator (2) inlet

Radiator (2) discharge to CPU cooler inlet

CPU cooler discharge to reservoir inlet

II. Installation of the cooling components

Warning!

Placement of the cooling components may vary depending on your chassis and motherboard configurations. A mock-up

installation is thus necessary to estimate the length of the different sections of tubing that will be required between each component.


The following is the recommended sequence of components installation.

1.

Radiator and fan

2.

Water-block(s)

Apogee water-block

MCW30 Chipset water-block

MCW60 VGA water-block

3.

Pump

4.

Reservoir