5. MCRES-M

ICRO RESERVOIR

I

NSTALLATION

‰ Installation


The MCRES-MICRO can be installed in any suitable
location meeting its form factor requirements. For
filling and bleeding purposes, it is preferable to hold or
to install the MCRES-MICRO at the highest point of
the liquid cooling loop. However, once filled and
hermetically closed, the reservoir can be installed
practically anywhere as long as it is kept upright as
shown in figure 1. Also, to facilitate the filling and
bleeding operations, you might want to wait until the
circuit has been filled-up before you fasten the
reservoir permanently to the chassis.


Fastening the device to the case: two mounting
methods can be used:

¾

Permanent mount with the provided mounting
hardware as shown in figure 1. Three holes will
need to be drilled for a permanent mount. Simply
use the reservoir as a template to mark the hole
locations, and use a 0.150” (4mm) drill bit to drill
the holes. Make sure to clean up any metal
shavings from the case once you are done.

¾

Easy mount, with the provided Velcro strips. This
is a fairly secure mount, as we use extra strong
Velcro. However, if your computer is to travel
often (LAN parties for example), a permanent
mount remains more suited for a more reliable
fastening of the device.


The only critical precaution to take when installing the
reservoir is to make sure that the discharge line (called
“Out to pump inlet” in the schematic) is directly
connected to the INLET of the pump.

In other words, the

pump (inlet) should be the first device connected to the
reservoir discharge. Using a different routing will make the
filling and bleeding of the circuit difficult, and may prevent
the pump to prime properly.

ITEM

NO.

PART NUMBER

DESCRIPTION

QTY.

1

MCRES-MICRO

Reservoir

1

2

1-4“ NPSM x 3-8“ and 1-2“barb

Barb fitting

2 pairs
each

3

O-RING-9557K473

Barb fitting O-Ring

2

4

pg7-o-ring

Fill-cap o-ring

1

5

pg7-plug

Pg7 Fill-cap

1

6

MOUNTING HARDWARE

3

90272A152-6-32x0500philips

6-32 x 7/8" (22mm) Philips screw

1

90760A007

6-32 Nut

1

washer-91007A614

Lock Washer

1

WASHER-RUBBER-437X150X092

Rubber Washer

1

7

panel

1

6a

6b

6c

6d