Parts

QTY PARTS

QTY

MCWRES-1000 reservoir

1

MCP350 12 Volts Pump, with RPM sensor

1

5 ¼” Rack

1

Worm-drive clamps

2

M3x6mm Philips screws

4

Fill-cap and O-ring

1

Preamble

In the context of a first time liquid cooling circuit installation, the MCRES-1000 should be the last component to be
installed.

The radiator inlet and outlet spigots must be oriented upwards during the filling procedure.

Physically disconnect the computer from the A/C power source while filing up the circuit. Disconnect the
motherboard from the power supply, and remove all unnecessary components such as CD-Rom and hard drive(s).

Proceed deliberately and frequently check your work. Rushing this procedure is not recommended

.

Two methods can be used to fill-up the reservoir:

Preferred (Chapter I): whenever possible, the reservoir should be filled before placing it in the CD-Rom bay.

Alternate (Chapter II): If your chassis configuration necessitates that the reservoir be installed in the CD-Rom bay
prior to filling, please refer to chapter II “

Alternate Filling Procedure

”.

I. F

IRST TIME INSTALLATION AND PREFERRED FILLING PROCEDURE

Step 1. Cutting the tubes to length: position the MCRES-1000 in
the desired CD-Rom drive bay, and cut sufficient length of tubing
in order to allow the assembly to slide back as shown above for
periodic maintenance purposes.

Step 2. Connect the discharge tube to the pump (coming from
either CPU inlet, or radiator for example), and the return line to
the reservoir inlet barb. Secure the tubes with the provided
worm-drive clamps. Tighten quite firmly, but not excessively as it
may result in crushing the plastic barbs.




Step 3. Rest the MCRES-1000P assembly on a paper towel or
cloth on top of the computer. Using a household funnel, fill-up the
reservoir with cooling fluid - slowly to avoid overflowing, until
the fluid reaches the appropriate level --------------

3. Appropriate level: up to the vent hole.