Serial number, Calibrate – Spektrum SPMR9900 DX9 User Manual

Page 23

Advertising
background image

23

SPEKTRUM DX9 • TRANSMITTER INSTRUCTION MANUAL

EN

Serial Number

The Serial Number screen displays the transmitter serial number

and AirWare software version.
Reference the Serial Number screen any time you need to

register your transmitter or update the AirWare software from the

Spektrum Community website.

Exporting the Serial Number to the SD Card

You may find it helpful to export the transmitter serial number to a

text file for your personal records or when you are registering the

transmitter on the Spektrum Community.
To export the transmitter serial number:

1. Insert an SD Card in the card slot on the transmitter.
2. Scroll to

EXPORT and press the scroll wheel. The SD Status

screen appears and should display MY_DX9.xml in the middle

of the screen.

3. Press the scroll wheel again to return to the Serial Number

screen.

4. Power off the transmitter and remove the SD Card from the

transmitter.

5. Install the SD Card in a card reader connected to your

computer.

6. Open the MY_DX9.xml file from the SD Card location. You

can then copy and paste the serial number into your personal

records or to the Spektrum Community website.

Locating the Transmitter AirWare Software Version

The transmitter AirWare software version appears between

PREV

and

NEXT at the bottom of the Serial Number screen. Register

your DX9 to get AirWare software updates and other news at

spektrumrc.com

IMPORTANT: AirWare files are specific to the transmitter

serial number and you cannot transfer AirWare files between

transmitters, ie., downloading an AirWare software update once

and attempting to install it on multiple transmitters.

Calibrate

The Calibration screen stores the potentiometer endpoints for all

proportional controls. It is mandatory to complete the calibration

after changing the stick mode selection.

Calibrating the Transmitter

1. Carefully move the gimbal sticks in a + shape moving from

left to right, then up and down. Press gently on the gimbals

at the stops to achieve an accurate calibration. Return both

gimbal sticks to the center position.

2. Move the Left and Right Side Levers to the top and bottom

positions, then move the side levers to the center position.

IMPORTANT: Only move one side lever at a time during

calibration.

3. Move the Knob to the full clockwise and counterclockwise

positions, then return the Knob to the center position.

4. Select SAVE to store the calibration.