Db-9 communications cable, Figure 2-6. 9-pin d-sub connector, Table 2-4. eia-232 serial port default settings -6 – ADC Network Unit User Manual

Page 18

Advertising
background image

Chapter 2: Installation

August 7, 2006

2-6

AIWN-UM-7001-01

DB-9 Communications Cable

An RS-232 Craft port is provided through a DB-9 connector. Refer to your work order to determine the required
communications connections. After determining the required connections, make the necessary connection.
Shielded cable is recommended and the maximum cable length is 50 feet. A 1:1 cable is required to connect this
port to the male DTE com port of a PC. Pinout information is shown in

Table 2-3

and

Figure 2-6

.

Table 2-3. EIA-232 DCE Control Connector (Female 9-Pin D-Sub)

Figure 2-6. 9-Pin D-Sub Connector

EIA-232 Communication Port Defaults

Host terminal or computer communication parameters must match the ENIU communication settings, see

Table 2-4

for default settings.

Table 2-4. EIA-232 Serial Port Default Settings

Pin #

Signal Name

I/O

Function

1

---

-

Not used

2

TXD

O

Transmit Data

3

RXD

I

Receive Data

4

---

-

Not used

5

GND

Signal Ground

6

---

-

Not used

7

---

-

Not used

8

---

-

Not used

9

---

-

Not used

Communication Parameter

Default

Baud Rate

115200

Data Bits

8

Parity

0

Stop Bits

1

No flow control