Performance and alarms – ADC Network Unit User Manual

Page 25

Advertising
background image

August 7, 2006

Chapter 3: Provisioning

AIWN-UM-7001-01

3-7

User and Privilege Settings

Purpose:

Defines users to the system.

Command: [SECURE privilege]

SET USER <name> RO|RW|SECURE <password>

CLEAR USER <name>

User name and passwords are specified as 1 to 15 alphanumeric characters.

Status Command: [SECURE privileges]

GET USERS

Performance and Alarms

Configure Alarm Thresholds

Purpose:

Configures the OAM alarm threshold and windows for CRC, Errored Symbol Period, Errored Frame Event, Errored
Frame Period, and Errored Frame Seconds Summary events.

Command: [RW,SECURE privilege]

SET [<interface>] <type> EVENT THRESHOLD <number> [WINDOW <number>]

• <interface> can optionally be specified to target a specific interface; when not specified, both interfaces are tar-

geted. <interface> must be either NETWORK or SUBSCRIBER.

• <type> is one of CRC|FRAME|FRAME PERIOD|FRAME SECONDS|SYMBOL PERIOD.

• <number> is an integer value whose range is dependent on the <type> and interface speed as specified by

IEEE 802.3ah. For convenience, MINIMUM and MAXIMUM are keywords that can be substituted for <number>
to set the values to the minimum and maximum values specified in IEEE 802.3ah.

• [WINDOW <number>] can be optionally specified; if not specified, the pervious value is retained.

Example: SET FRAME PERIOD EVENT THRESHOLD 1

Example: SET SUBSCRIBER CRC EVENT THRESHOLD MINIMUM WINDOW MAXIMUM

Status Command: [all privileges]

GET [NETWORK|SUBSCRIBER] EVENT THRESHOLD

GET [NETWORK|SUBSCRIBER] ALARM STATUS

Advertising