ROTHENBERGER RODIA DRY CLEANER 1200 User Manual

Page 14

Advertising
background image

12

ENGLISH

Instantly switch off the appliance if foam or water leaks out. Empty the container and folded filter.

Acids, acetone and solvents can etch appliance parts.

A damaged appliance connecting cable must only be replaced with a special connecting cable
available from the manufacturer or the after-sales service.

2

Technical Data

Rated capacity ............................ 1200 W

Maximum capacity ...................... 1400 W

Frequency .................................. 50 / 60 Hz

Connecting cable ........................ H05VV F 3 x 1,5

Protection class .......................... I

Type of protection ....................... IP 24

Typical A-rated sound level:

Noise pressure level (L

pA

) ........... 69,5 dB (A) ¦ K

pA

3 dB (A)

Sound power level (L

WA

) ............. 80,5 dB (A) ¦ K

WA

3 dB (A)

The noise level during operation can exceed 85 dB (A). Wear hearing protection!

Measured values determined in accordance with EN 61029-1:2010.

3

Function of the Unit

3.1

Overview

(A)

1

Top section

4

Locking bar

10

Wheels

2

Functional plate

5

Lock

11

Steering castors

2a

Rotary switch ON/
OFF/Automatic/Vibration

6

Connecting line

12

13

Filter cassettes

Motor protecion filter

2b

Power socket for electric
tools

7

Container

14

Paper filter bag

(optional accessory)

2c

Volume flow display

8

Suction opening

15

Vacuum hose

3

Cold air inlet

9

Snap-in locks

3.2

Setting into operation

When unpacking, check that the appliance is complete and that there is no transport damage.

Mounting the Vacuum hose

Mount the vacuum hose (15) onto the hose connection piece (8) and turn it in clockwise direc-
tion to the stop.
Electrical equipment

The appliance is switched ON/OFF with the switch (2a) (see fig. A on the top section (1) of the
appliance), or switch to automatic or vibration mode.

0

Suction >off<

I

Suction >on<, (manual operation)

A

Ready for ON/OFF automatic switching system (the vacuum cleaner is switched on and
off by the connected electric tool).

R

Filter cleaning function; in this setting the vibrator will operate for 7 seconds after which it
will be automatically turned off.

AR

Appliance version featuring “AR“ can be operated as described under “A“ except that
automatic

filter cleaning (as described under “R“) is turned on when the volume flow

display lights up.

The power socket (2b) is intended for the connection of an electric tool.

Advertising