ROTHENBERGER RODIADRILL Ceramic ECO User Manual

Page 16

Advertising
background image

12

ENGLISH

Dust that arises during work is often harmful to health and should not be allowed to enter the
body. Please wear a suitable dust protection mask.

Please remove the plug from the electric socket before all work on the equipment.

Be sure the equipment is switched off before connecting it to the electric socket.

Always keep the connecting cable away from the sphere of action of the equipment. Always
guide the cable away from the equipment to the rear.

Please look out for electric cables, gas and water pipes when working on the wall, ceiling or
floor.

Protect the equipment against splash water. Do not work over head!

2

Technical Data

Nominal acceptance power ......... 800 W

1. Gear

2. Gear

Speed ......................................... 3600 min-1 ......... 6400 min-1

Drilling diameter .......................... Ø 25 – 67 mm ..... Ø 6 – 25 mm

Drilling range ..............................

Masonry

Ø 40 x 400 mm

Concrete

Ø 35 x 150 mm

Tile

Ø 6 – 67 mm

Tool fitting ................................... Quick change adapter with G 1/2" fitting

Weight ........................................ approx. 3,4 kg; Ceramic ECO approx.3,2 kg

Vibration ..................................... 2,6 m/s2

Drill bit types ...............................

High Speed Plus, No. FF44806

– FF44868

SPEED STAR DX, No. FF00610

– FF00665

Typical A-rated sound level:

Noise pressure level (L

pA

) ........... 91 dB (A) ¦ K

pA

3 dB (A)

Sound power level (L

WA

) ............. 102 dB (A) ¦ K

WA

3 dB (A)

The noise level during operation can exceed 85 dB (A). Wear hearing protection!

Measured values determined in accordance with EN 60745-1:2010.

3

Electric supply

Only connect to one-phase alternating current and to the mains voltage indicated on the power
rating plate.

3.1

Putting the PRCD switch into operation

Only suitable for AC current! Note the mains network voltage!

Perform the following test procedure on the PRCD switch before every putting into operation of
the device:

1. Connect the PRCD plug connector with the socket.

2. Press on RESET. The indicator switches to ORANGE (ON).

3. Pull the plug connector out of the socket. The display switches itself off.

4. Repeat 1. and 2.

5. Press on TEST. The orange indicator switches itself off.

6. Press on RESET to switch the device on (ORANGE).

These protective device protect against faults in the attached device, not against such
faults in the preceding plant.


Advertising