5.4.6 Transport/storage
Make sure to observe the instructions under section “Transport/Storage“.
5.5
Set temperatures on temperature controller
The default settings for the melt and air temperatures of the hand
extruders are shown in the following temperature chart. (The
values have been determined with the aid of reference materials.)
Temperature chart:
Material Melttemperature Airtemperature
PP
200 – 240 °C
250 – 300 °C
PE
200 – 240 °C
250 – 300 °C
PVDF
240 – 260 °C
280 – 350° C
If other temperatures are needed, the corresponding settings can be made on the temperature
controller.