Hi-Limit Reset Button

A Hi-Limit Control turns off electrical power to the

heater and control circuits if the platen overheats. To

reset the control, allow sufficient time (10-15 minutes)

for the unit to cool, then locate the Reset Button at

the rear of the unit. Remove the black protective cap,

press the Reset Button, and reinstall the protective cap

(Figure 2).

NOTE: If the unit requires continuous resetting,

contact your Authorized Service Agency.

Fault Codes

OPERATION (continued)

Table 2

OLD STYLE

CONTROL BOARD

FAULT CODE

ON DISPLAY

FAULT CODE DESCRIPTION

“HI” Flashes on

display

The platen thermocouple is disconnected

or open or the platen relay is shorted.

Call for service.

“HI” and “LO”

flashes at cold

start up

The auxiliary thermocouple is discon-

nected or open. Call for service.

“HI” and “USE”

flashes after 30

minutes of pre-

heat time

The auxiliary thermocouple is discon-

nected or open or the auxiliary relay is

shorted. Call for service.

“CHEC”

The electrical compartment ambient

temperature is above 140° F (60° C). All

heaters will shut off. Check for proper air-

flow. Call for service.

“PO”

The incoming voltage has dropped below

175 VAC. All heaters will shut off. Call for

service.

NEW STYLE

CONTROL BOARD

FAULT CODE

ON DISPLAY

POSSIBLE CAUSE(S)

Err 1

Failed Control Board (Call for Service)

Err 2

Failed Control Board (Call for Service)

Err 3

The programming dip switches were not

adjusted upon installation of the universal

control board. The dip switches must be

adjusted to match the toaster Mfg #. Refer

to document P/N 1011052 for specific set-

tings.

Err 4

Platen Thermocouple is shorted to chassis

ground (Call for Service)

Err 5

Platen Thermocouple is Loose or Discon-

nected or Open (Call for Service)

Err 6

Failed Control Board (Call for Service)

Err 7

Failed Control Board (Call for Service)

Err 8

Failed Control Board (Call for Service)

Err 9

The programming dip switches were not

adjusted upon installation of the universal

control board. The dip switches must be

adjusted to match the toaster Mfg #. Refer

to document P/N 1011052 for specific set-

tings. NOTE: If the dip switches were ad-

justed correctly, then the AC Isolator Board

or its wiring is faulty. (Call for Service)

Err 10

Failed Control Board (Call for Service)

CHEC

Ambient in electrical compartment has

exceeded 140 F (60 C). Check for proper

airflow. (Call for Service)

Table 1

If the toaster control board

resembles the OLD style

shown here, refer to the

Fault Message in Table 1.

If the toaster control board

resembles the NEW style

shown here, refer to the

Fault Message in Table 2.