Control board – A.J. Antunes & Co MT-12 9200148 User Manual

Page 10

Advertising
background image

10

P/N 1010918 Rev. E 03/13

Dip Switch Settings

Check your Control Board assembly to
insure the Dip Switch settings are correct.

NOTE: Refer to the table below for a list-
ing of Manufacturing numbers that use
the 220 or 200 setting.

DO NOT USE HIGH SETTING.

Mfg. No.

200 or 220?

LO or High?

9200139

220

LO

9200146

200

LO

9200148

220

LO

MADE IN U.S.A.

ANTUNES CONTROLS

SFT00-0216-B

1

YELLOW

RED

1

2

PARTIAL

DS1

-

+

LED

DONE

SW

PARTIAL

BUZZER

ON

SSR

THERM.

FAULT.

SW

FULL

PARTIAL

FULL

200
HIGH
B
D

A
C

LOW

220

+

-

DS1

C35

C31

J3

J2

C7

C22

C4

C12

C8

C18

C2

C1

C6

C5

C27

C15

C19

C11

C23

C28

C

21

C30

C24

C33

C29

C34

C26

C16

C20

C32

C25

C17

C9

C13

C3

C14

C10

CRY1

CR8

CR10

CR9

BR2

BR1

L2

L6

L5

L3

U5

L4

L1

CR13

CR14 CR15

CR16

CR17

CR18

CR19

U2

U4

U3

U1

R27

R29

R46

R41

R51

R31

R20

R43

R40

R44

R38

R36

R47

R49

R42

R52

R50

R39

R14

R37

R24

R23

R10

R48

R54

R53

R13

R4

R34

R7

R21

R5

R2

R18

R11

R8

R15

R33

R22

R45

R12

R32

R9

R6

R3

R17

R35

R30

1

4

3

2

P1

1

P2

1

P4

U6

Q3

Q2

Q1

Q4

VA

R1

VA

R2

VRL1

P3

1

2

3

R16

R1

1

2

3

LOW

HIGH

200

220

A

B

C

D

Control Board

Advertising