DIAGNOSTIC FLOW CHART

Turn toaster on, toaster

performs self-test

Toaster Passes Self-

test

Both indicator lights flash and an Audio

Signal beeps twice to indicate success-

ful self-test

Heats to more than 105°F (65°C)

but less than 750°F (400°C) in 30

minutes

BEEP CODES

2 Beeps = Voltage too low
3 Beeps = Toaster temperature more than 750°F

(400°C) after 30 minutes

4 Beeps = Toaster temperature less than 150°F (65°C)

after 30 minutes

5 Beeps = Thermocouple disconnected or broken
NOTE: All beep codes are followed by a 2 second
pause, then repeated.

IMPORTANT

Beep Codes

(errors) can occur any

time during operation.

Less than 150° F (65°C) (Control

turns solid state relay off). Audio

signal beeps 4 times, waits 2

seconds, beeps 4 times, waits 2

seconds, and continues until unit

is turned off

More than 750°F (400° C) (con-

trol turns solid state relay off)

Audio signal beeps 3 times, waits

2 seconds, beeps 3 times, waits 2

seconds and continues until unit

is turned off

Refer to

Troubleshooting

Yes

Yes

Yes

No

No

No

Heats to more than 105°F (65°C)

but less than 750°F (400°C) in 30

minutes

Yes

Door is opened during cook cycle

- Audio Signal beeps once every

second door is open

No

Door is open for more than 8 consecutive seconds

during cook cycle - Audio Signal beeps very

rapidly 15 times - cook cycle is automatically

cancelled.

No

Yes

Yes

Toaster times-out for:

Partial Load (85-125 sec) or

Full load (90-130 sec.)

Unit beeps 2 times per second until front door is opened.

NOTE: Push partial load control knob to turn off partial load light.

Product is too

light

No

Product is too

dark

No

Refer to Troubleshooting

Yes

Product toasted properly

Yes