DISPLAY CABINET HEATED

P/N 1010772 Rev. D 12/13

MAINTENANCE (continued)

Display Codes

This section describes the different display codes and

their meanings.

TEMP

UP

TEMP

DOWN

TEMP

SCALE

F

C

O

O

“LO” flashes during the initial warm up period. The unit

continues to display this code until the unit reaches the

setpoint temperature. When the unit reaches the set-

point temperature, it displays the setpoint temperature.

This figure shows an example setpoint temperature of

150° F displayed on the console.

“HI” flashes if the actual cabinet temperature exceeds

the setpoint temperature or if the thermistor has short-

ed.

NOTE: The thermistor should be 100k ohm +/- 2% at

room temperature.

“OPEN” flashes if the thermistor is OPEN or discon-

nected. The unit will not call for heat.

NOTE: The thermistor should be 100k ohms +/- 2%

at room temperature.

“PO” In 120 VAC units, this code flashes if the supply

voltage is below 100 VAC or above 135 VAC. In 220/

240 VAC units, this code flashes if the supply voltage is

below 190 VAC or above 265 VAC.

NOTE: If voltage is within normal ranges, then the

Control Board is faulty.

To reset a unit in this state, the supply voltage must be

within acceptable limits and the unit must be turned off

for a few seconds and then turned back on.