System Sanitization

The system and downstream plumbing should be sanitized

every six months. When necessary, follow the procedure in

Sanitizing the System and Lines in the Installation section

of this manual.

O-ring

TAC

Housing

TAC

Cartridge

TAC

Head

Red Pressure

Relief Button

Gasket

TAC

Housing

TAC

Cartridge

Figure 10. Removing the TAC Housing (VZN-441V-T5 only)

Figure 11. Replacing the TAC Cartridge (VZN-441V-T5 only)

Rinsing and Replacing the TAC Cartridge

(VZN-441H-T5 ONLY)

NOTE: Do not perform this procedure with a new Carbon

Element installed.

1. Turn off water to the system by closing the Inlet Ball

Valve and then close the Outlet Ball Valve.

2. Press the

FLUSH button to initiate the flush cycle.

Repeat several times to ensure the permeate tank is

empty.

3. Press and hold the Red Pressure Relief Button on the

top of the TAC Housing (Figure 11) to lower the water

level inside the housing by 2 to 3 inches.

4. Remove the TAC Housing (Figure 10).
5. Empty any water into a drain and discard the old TAC

Cartridge (Figure 11).

6. Inspect the O-ring on the TAC Housing. Replace the

O-ring if it is cracked, twisted, or missing.

7. Lubricate the O-ring with an approved food grade

lubricant and install into the TAC Housing.

8. Install the new TAC Cartridge into the TAC Housing with

the arrow on the cartridge pointing up.

NOTE: Make sure the End Seal gaskets are in place in

the recessed grooves on both ends of the TAC Cartridge

(Figure 12).
9. Screw the TAC Housing (containing the TAC Cartridge)

into place on the TAC Head. The Housing will come

to a hard stop at the end of the thread. Use a Filter

Wrench if necessary.

10. Direct water from the Rinse Ball Valve to drain.
NOTE: It is important to direct the Rinse Ball Valve to a

drain as the water resulting from the flush should NOT be

used.
11. Turn on the water to the system by slowly opening the

Inlet Ball Valve and allow water to flow through the TAC

Cartridge and Housing to clear out trapped air and any

carbon fines that may be present.

12. To help remove trapped air from the TAC Housing,

press the Red Pressure Relief button on the top of the

Housing until water just begins to come out.

13. Rinse the TAC Cartridge for at least 5 minutes.
NOTE: Do NOT consume the water used for rinsing the

TAC Cartridge.
14. When the TAC Cartridge rinsing is complete, close the

Rinse Ball Valve and open the Outlet Ball Valve.

15. Reconnect the water to service. The system is now

ready for use.