Vzn v series, Important safety information – A.J. Antunes & Co VZN-441V-T5 9700766 User Manual

Page 4

Advertising
background image

VZN V SERIES

4

P/N 1011144 Rev. C 05/13

IMPORTANT SAFETY INFORMATION

In addition to the warnings and cautions in this manual, use

the following guidelines to safely operate the system:

• Read all instructions before using equipment.

• Install or locate the equipment only for its intended use

as described in this manual.

• Do NOT use corrosive chemicals in this equipment.

• Do NOT operate this equipment if it has a damaged

cord or plug; if it is not working properly, or if it has

been damaged or dropped.

• This equipment should be serviced by qualified person-

nel only. Contact A.J. Antunes & Co. for repair.

• Do NOT immerse cord or plug in water.

• Keep cord away from heated surfaces.

• This equipment should be supplied with only cold

water.

• For installations in Massachusetts, the Commonwealth

of Massachusetts Plumbing Code 248 CMR shall be

adhered to. The use of saddle valves are not permitted.

Please consult your local plumber.

The following warnings and cautions appear throughout this

manual and should be carefully observed.

• Unplug the power cord before performing any

service or maintenance on the unit.

• All electrical connections must be in accordance with

local electrical codes and any other applicable codes.

• WARNING ELECTRICAL SHOCK HAZARD. FAILURE

TO FOLLOW THESE INSTRUCTIONS COULD

RESULT IN SERIOUS INJURY OR DEATH.

- Do NOT modify the power supply cord plug. If it

does not fit the outlet, have a proper outlet installed

by a qualified electrician.

- Do NOT use an extension cord with this unit.

• If the supply cord is damaged, it must be replaced by

the manufacturer, its service agent, or a similarly quali-

fied person.

• This equipment is to be installed to comply with the

local plumbing code and any other applicable code.

• Water pressure must not exceed 100 psig (690 kPa).

To reduce water pressure, install a water pressure

regulator and set to suit the application.

• The trans membrane pressure (inlet pressure minus

the permeate water pressure) must not exceed 45 psi

(310 kPa).

• A ground fault circuit interrupter (GFCI) must be

installed on the circuit to this system.

• When installed on metallic plumbing, a properly sized

electrical bonding jumper must be installed across the

inlet and outlet pipes serving this unit.

NOTE: If the inlet water pressure is less than 50 psig (345

kPa), it is recommended that a suitably-sized booster

system (outlet pressure 60 psig - 100 psig max (414 kPa -

690 kPa max) be installed.