SMD Installation Information

1-630-784-1000 Fax: 630-784-1651

Page 2 of 4

P/N 1011083 06/10

1-800-253-2991

Air Connections

Tubing recommended as minimums: 1/4” copper or alu-

minum tubing, or 1/8” pipe. All tubing and pipe must be

clean and free from oil, dirt, and chips. If piping runs over

five feet long, use a larger size tubing or pipe, and reduce

size at switch.

Air Supply

Should be connected as shown in the drawings below.

Always leave unused ports open to the atmosphere.

Standard Inlet Locations (1/8” NPT without

fittings)

Pressure
Connection

High Vacuum or
(Low Pressure)

Low Vacuum or
(High Pressure)

Negative

(Vacuum)

Inlet

Negative

(Vacuum)

Inlet

Positive

(Pressure)

Inlet

Positive

(Pressure)

Inlet

One side inlet and one machine

thread adapter with nut

(Specify 1-14 UNS).

Specify Other Inlet Locations

Side inlets.

PRESSURE ONLY

VACUUM ONLY

DIFFERENTIAL INLET CONNECTION