Evaporator installation (indoor), I) drainage, Ii) connective pipe – Alen AMS12 12000 BTU AND 13.5 SEER User Manual

Page 10: 2) connective pipe and drainage installation, Iii) piping and bandaging, 3) evaporator (indoor) unit installation, Evaporator (indoor) unit

Advertising
background image

i) Drainage

Run the drain hose downward.
Do not install the drain hose as illus-
trated below.

Do not form a rise

Do not put the hose

end into water

a) For the left-hand and right-hand piping,
remove the pipe cover from the side panel.
Explain to the customer that the pipe cover
must be kept as it may be used if the air
conditioner is moved to another location.

b) For the left-hand and rear-left-hand pip-
ing, install the piping as shown. Bend the
connective pipe to be
placed at a height of 1 5/8 inches
or less from the wall.

ii) Connective Pipe

Pipe holder

Pipe cover

Right piping

Right back piping

Pipe Cover

Left back piping

Left piping

2) Connective Pipe and Drainage Installation

c) Fix the end of the connective pipe.
(Refer to Tightening Connection in
Refrigerant Piping Connection).

Connective Pipe

Evaporator (Indoor) Unit outline

iii) Piping and Bandaging

Connective Cable

Ponding Box

Pipe Room

Connective Pipe

Wrapping Belt

Drain Hose

Wind the Connective cable, drain hose
and wiring tape securely, evenly as
shown below.

Evaporator (Indoor) Unit

i) Pass the piping through
the hole in the wall

ii) Put the upper claw at

the back of the installation
plate, move the evaporator
(indoor) unit from side to
side to see if it is securely
hooked.

iii) Insert a spacer between the evaporator
(indoor) unit and the wall bracket to sepa-
rate the bottom of the unit from the wall.

iv) Push the lower part of the evaporator
(indoor) unit up on the wall. Then move
the evaporator (indoor) unit from side to
side, up and down to check if it is hooked
securely

.

3) Evaporator (Indoor)

Unit Installation

EvAPORATOR INSTALLATION (INDOOR)

9