Appendix g - technical specifications – ACR Electronics PLB-350C User Manual

Page 30

Advertising
background image

Y1-03-0244B

30

APPENDIX G - TECHNICAL SPECIFICATIONS

406 MHz Transmitter
Frequency

406 MHz

Output Power

greater than 5 watts (typical: 6.3 watts)

Frequency Stability

±2 parts per billion/100ms

Digital Message:
Format

Long message

Serialized

1*

Message protocol

Standard Location

Duration

520 ms

Rate

400 bps

Encoding

Biphase L

Modulation

±1.1 radians peak

1*

Beacons are shipped from ACR with a Serialized code but can be reprogrammed at a service

center to other coded formats including nationality of registration.

121.5 MHz Transmitter

Frequency:

121.5 MHz

Frequency Tolerance

±50 ppm

Output Power

>25 mW PEP (typical 80mW)

Morse Code “P” ID

Every 50 seconds (approximately) (U.S. Protocol)

Modulation
Type

AM (3K20A3N)

Sweep Range

400 to 1200 hZ

Sweep Rate

3 Hz

Duty Cycle

37.5%

Morse P

AM (2K00A2A)

Antenna
Frequency

406.037 & 121.5 MHz

Polarization

Vertical

VSWR

Less than 1.5:1

General/Environmental

Minimum

Battery

Operating Life

+24 hours minimum @ -4°F to +131°F (-20°C to +55°C)

Battery

Replacement

Interval

Battery replacement due no later than 6 years from date of
manufacture, 5 years from date of install, or after emergency use

*Batteries meet the UN Classification for Non-dangerous goods

Size

of

beacon

less

Antenna

2.31 x 5.81 x

1.25 in (5.87 x 14.76 x 3.17 cm) (SARLink™ View)

2.31 x 5.81 x 1.45 in (5.87 x 14.76 x 3.68 cm) (AquaLink™ View)

Material

High-impact and UV-resistant plastic

Color

ACR-

treuse™ (High-visibility yellow)

Weight

8.9 oz (252 g) without belt clip (SARLink™)
9.2 oz (260 g) without attachment clip (AquaLink™)

Strobe Light

Bright White, I flash per 3 seconds

Digital Display

Blue, 1 inch

Waterproof

Factory tested to 16.4 ft (5 m) for 1 hour and to 32.8 ft (10 m) for 10
minutes, both at room temperature

Buoyancy

See section 5

“Distinguishing PLB Features”, page 8

Temperature Range
Operating

-4°F to +131°F (-20°C to +55°C)

Storage:

-40°F to +158°F (-40°C to +70°C)


PLB-350C meets the requirements of Federal Communications Commission
(FCC) Part 95 Subpart K. For all other type approval information, please visit
our website at

www.acrelectronics.com

.