Fault

Cause

Remedy

Pump runs but does not
transport

Air in the pump

Plug in/ pull out the mains
plug of the pump a few
times till the fluid gets
sucked

Suction area blocked

Pull out the mains plug and
clean the suction area

(only in manual mode) Wa-
ter level below the minimum
water level

Where possible, immerse
the pump deeper into the
liquid or proceed according
to the instructions in the
chapter describing the prep-
arations necessary for auto-
matic operation

Pump does not run or sud-
denly comes to a standstill
during operations

Power supply interrupted

Check fuses and electrical
connections

Thermal protection switch
has switched off the pump
due to over-heating

Pull out the mains plug, let
the pump cool down, clean
the suction area, prevent
dry running

Dirt particles have got
jammed into the suction
area

Pull out the mains plug and
clean the suction area

Pump operation stopped by
sensor

Check position of level sen-
sor

Pumping capacity is reduc-
ing

Suction area blocked

Pull out the mains plug and
clean the suction area

Pumping capacity too low

The pumping capacity de-
pends on the flow height,
hose diameter and hose
length.

Keep max. flow height, see
technical data. If necessary,
select a different hose diam-
eter or hose length.