A&D Waterproof Digital Platform Scale HW-60KV-WP User Manual

Page 38

Advertising
background image

Page 36

HV-WP/HW-WP Series

13. Simple Batch Function

13.

13.

13.

13. Simple Batch Function

Simple Batch Function

Simple Batch Function

Simple Batch Function

This function compaires a display value with the final value, preliminary value and
zero band for the full/dribble batch function. The result is indicated by zero band (LO
indicator), full flow (HI indicator) and dribble flow (OK indicator). Even if a weighing
value includes increase and decrease, this function can compare it.

Set the parameters of the "simple batch function (

f6 8

)", in the function table, final

value (HI), preliminary value (OK) and zero band (LO), in advance, to use this function.

Install option OP-03 or OP-04, to use the relay output of the comparison.

Install option OP-03, to use the buzzer output of the comparator.

Comparison Condition

Gross < Zero band.............. LO is displayed and output.

Final - Preliminary ≦ Net ........................ OK is displayed and output.

Final ≦ Net ........................ OK, HI is displayed and output.

Parameter List and Word Definition

The "gross" is a total measurement value where the tare value is not subtracted.
The "net" is a measurement value with a tare value subtracted from the gross.
The "tare" is an item put on the weighing pan and its mass is subtracted from the gross.
The "zero band" is the zero detection level.
The "zero point" is the fundamental starting point to weigh anything.

Function table

Meaning and purpose

A

f6 8

Simple batch function

A

Advertising