Changing/adding oil, Stop, Maintenance/care – ACDelco AC-G0003 User Manual

Page 20

Advertising
background image

MAINTENANCE/CARE

Proper routine maintenance of this generator is essential for safe, economical, and trouble-free operation. It will help prolong the life of this generator

as well as help reduce air pollution. Perform maintenance checks and procedures according to the schedule in Figure 10.

STOP!

If you have questions about any maintenance procedures described in this manual, call 1-866-460-9437 , Monday - Friday, 8 AM - 4 PM Central

Time.


Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance

procedures. Keep heat, sparks and flame away.

Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause

death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual.

Recommended Maintenance Schedule

Each Use

Every Month or
Each 20 Hrs

Every 3 Months or
Each 50 Hrs

Every 6 Months or
Each 100 Hrs

Every Year or
Each 300 Hrs

Engine Oil

Check Level

X

Replace

X

Air Filter

Check

X

Clean X

Fuel Filler Cap

Clean

X

Spark Plug

Check/Clean

X

Fuel Tank

Verify Gas Level

X

Clean

X

Figure 10 - Recommended maintenance schedule

Cleaning the Generator

Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush,

vacuum and/or pressurized air.

Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion.

Never use gasoline to clean parts of this generator.

Checking the Oil Level

Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil, it is important to check the oil level in the

engine crankcase before each use to ensure that there is a sufficient quantity.


To check the oil level:
1. Verify that this generator is shut down and on a level surface.

2. Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 11.

3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap.

4. Insert the dipstick as if replacing the cap and then remove again. There should be oil on the dipstick. If there is no oil on the dipstick, or oil is

visible only at the very end of the dipstick, add oil until the engine crankcase is filled (see “Changing/Adding Oil” in this section of this manual).

5. Confirm that the oil filler/dipstick cap is properly in place when finished verifying the oil level.

Model AC-G0003 5500 Surge Watts / 5000 Running Watts Portable Generator

20

Advertising