The Ventless Hood is factory installed directly on

the top of the Alto-Shaam

®

Rotisserie oven. The hood

is designed to vent clean air back into the kitchen,
filtering vapors and grease. A high-power fan draws
fumes and steam into the hood intake and out the top
surface exhaust vent. Fumes and vapors are circulated
through filters. An activated charcoal filter cleans the
air before venting it out the top of the hood.

Turn the ventless hood ON before operating the

rotisserie oven. There are a number of safety features
incorporated into the operation of the hood which are
directly related to the interaction of hood function and
the operation of the rotisserie oven.

VENTLESS HOOD INTERLOCK SWITCHES

— CHARCOAL FILTER SWITCH

GREASE FILTER SWITCH
Prevents both hood and oven operation if any filter
is not in place or is improperly installed.

— FAN PRESSURE SWITCH: Prevents rotisserie

oven operation if hood fan is not operating or if
the filters are more than 25% blocked.

RESET SWITCH

— The Reset has to be used if the rotisserie oven is

turned on before the hood or if the hood was opened.
It resets the pressure switch circuit and provides
power to the rotisserie control circuit. This switch
must also be used to reset hood controls after any
problem with the filters. See illustrations on following
pages of this manual.

N O T E :

If the filters are dirty or in need of replacement
the hood will not reset and the rotisserie will
not operate until they have been cleaned
and/or replaced.

VENTLESS HOOD CONTROL

H O O D O P E R AT I O N

E L E C T R I C A L C O N N E C T I O N

1. An identification tag is permanently mounted on the base of the unit.

2. The interconnect cord from the ventless hood to the rotisserie oven provides full power connection.

U N PA C K I N G & S E T- U P

The Alto-Shaam Ventless Hood has been thoroughly tested and inspected to ensure only the highest quality

unit is provided. When you receive your hood, check for any possible shipping damage and report it at once
to the delivering carrier.

Save all the information and instructions packed inside the carton. Complete and return the warranty card

to the factory as soon as possible to assure prompt service in the event of a warranty parts and labor claim.

NOTE: All claims for warranty must include the full model number and serial number of the hood.

FAN INDICATOR LIGHT
I l l u m i n a t e s w h e n
f a n i s r u n n i n g .

ON/OFF SWITCH

RESET BUTTON
P r e s s a f t e r
c o r r e c t i o n o f a n y
p r o b l e m w i t h
h o o d o r o v e n .

A R - 7 E R o t i s s e r i e w i t h A R - 7 V H Ve n t l e s s H o o d O p e r a t i o n & C a r e M a n u a l • 3 6

V E N T L E S S H O O D

Advertising