8. STARTUP & ADJUSTMENT

1. After plumbing and wiring are complete, close the

service valve to allow startup without pressurizing
the entire plumbing system. If a service valve was not
installed, close all fixtures in the home. Ensure the
bottom drain is closed.

2. Restore power to the Well-X1

by turning on the

breaker and electrical service switch (if installed). The
display will illuminate.

3. The display will read "88" to test the display illumination,

then a number identifying the control type (i.e.

07). This

number is for factory use and may vary by model and
manufacture date.

4. After a slight pause, the pump will start and the system

pressure will be displayed. This number will increase
as the pump runs and the tank fills.


Note: Some jet pumps may be difficult to prime,
resulting in the low water cut-off activating if pressure
will not build above 10 psig. Depressing the

s

arrow

will temporarily override the low water cut-off to allow
proper priming.