IGNITION MODULES

3-3

GM 7 & 8 pin modules only:

– Reconnect test leads as shown in Test 2

diagram.

– Observe PULSE light. It should NOT be

flashing. If PULSE light flashes, module is bad.

– Short pins E and R together using paper clip (or

other metal jumper).

– Observe PULSE light for test results.

• Flashing light means good module. (There may
be a short delay before flashing starts.)

• No flashing means bad module.

Ford modules with two test hook-ups:

– Reconnect test leads as shown for Test 2. (Only

the Green test lead is moved.)

– Observe PULSE light for test results.

• Flashing light means good module. (There may
be a short delay before flashing starts.)

• No flashing means bad module.

6) Testing is complete.

Set RANGE switch to POWER OFF and remove all

test leads.