Section 4

4-2

Continuity Checks

Test wiring, ground connections, switch operation, relay contacts, or similar.

Important:

• Do continuity tests on unpowered circuits only.

• Always make sure all connections are good. If necessary, scrape away

corrosion, paint, etc. at the contact points.

Warning: If working on-car, turn ignition key OFF and observe all safety
precautions (see page ii).

1) Set RANGE switch to HIGH.

2) Set FUNCTION switch to OHMS.

3) Connect YELLOW test lead to one end of circuit (such as

wire, switch or relay contact).

4) Connect BLACK test lead to other end of wire, switch or

relay.

RANGE

HIGH

LOW

POWER OFF

FUNCTION

VOLTS

OHMS

FREQUENCY

5) TEST light position indicates

amount of continuity.

• All TEST lights OFF - Short Circuit

(measured resistance is 200 ohms,
or less).

• Top TEST light ON - Open Circuit

(measured resistance is 7 Kohms,
or higher).

Other TEST lights ON mean circuit has
resistance between 200 ohms and 7 K
ohms.

Low Resistance Checks

• RANGE switch on LOW.

• FUNCTION switch on OHMS.

• Use YELLOW and BLACK test leads.

All TEST lights OFF - resistance is 30 ohms, or less.

Top TEST light ON - resistance is 300 ohms, or higher.

Other TEST lights ON mean resistance is between 30 ohms and
300 ohms.

TEST

TEST

Yellow

Short

circuit

Yellow

Open

circuit

Black

Black

FUNCTION

VOLTS

OHMS

FREQUENCY

RANGE

HIGH

LOW

POWER OFF