Drainage, Controls – Amcor D950E User Manual

Page 6

Advertising
background image

GB

There are four optional outlets for the

drainage tube. To change the outlet of

the drainage tube the rear panel should

be dismounted.

When remounting the rear panel care

should be taken to return all the screws

and washers to their original location.

Connecting the permanent outlet

• Connect the pipe to an outlet tube with

the correct diameter.

Drainage

Drainage

See page 3, fig. 4

ON/OFF

(1)

The unit is switched on and off by

pressing the ON/OFF button (1). When

the unit is on, the fan runs in the set

speed.

Humidity

(2)

Press the HUMIDITY button (2) repeatedly

to choose the desired level of relative

humidity in the area. The corresponding

control lights (2) will indicate the selected

percentage. The yellow CNT control light

(5) indicates that the unit is running

continuously, disregarding the relative

humidity level in the area.

Ventilator speed

(3)

Press the SPEED button (3) to select low

or high speed. The corresponding control

light (3) will indicate this, Lo=low or

Hi=high.

Controls

Controls

Digital display

(4)

The digital display (4) will show the

measured relative humidity in the area.

Compressor

(6)

The COMP control light (6) will be on

when the compressor is running. An

automatic time delay of five minutes

before the compressor can (re-)start

working is a safegarde against damage.

IMPORTANT:

This dehumidifier should not be used in

temperatures below 7 °C or above 35

°C.

Defrost Control

The dehumidifier is equipped with an

automatic de-icing mode to defrost the

refrigeration coil during low temperature

operation. The compressor is switched

off whilst the ventilator continues to run.

• Push the other end of the tube into a

drain, making sure that the tubing

cannot be twisted or folded.

• The entire length of the tube must be

slightly inclined.

• Ensure that the outlet of the drainage

pipe is NOT under the water level in

the drain.

NOTE

: In very cold weather conditions

precautions should be taken to prevent

the drainage pipe from freezing.

6