If the dehumidifier does not operate:

• Make sure the unit is plugged in.

• Ensure the humidistat control is turned on.

If the unit is noisy:

• Make sure the dehumidifier is standing solidly and level.

If the unit is leaking:

• Check the drainage tube for correct fitting.

• Check for twists and bends in the drainage tube.

• Check the drainage tube for a sufficient slope.

• Check and make sure that the outlet of the drainage pipe is not under the

water-level in the drain.

See page 3, fig. 2

Cleaning the air filter

Air circulation is impeded and the

efficiency of the dehumidifying and air

purifying functions decreases when the

filter is dirty. It is therefore good practice

to clean the filter at regular intervals. The

precise intervals depend on the room in

which the appliance operates and on

how frequently it is used.

Cleaning

Cleaning

Trouble shooting

Trouble-shooting

• Remove the filter (4) by sliding it out.

• Clean the filter or wash in tap water.

• Dry the filter before inserting it back.

Housing

Wipe regularly clean with a moist cloth

and mild household detergent.

Servicing

Have your dehumidifier once a year

serviced by a qualified engineer.

Disconnect from the mains before cleaning the unit or any of its components.

Specifications may change without prior notice.

Meets EEC directive 73/23/CE (LVD).

D850E

D950E

Mains

230 V/50 Hz

Power consumption

850 W

1200 W

Current (operation)

4.5 A

6 A

Current (at start)

18 A

24 A

Water extraction
(at 30 °C, 70% RH)

45 L/24h 60 L/24h

Refrigerating agent

R407C

D850E

D950E

Airflow

500 m

3

/h 680 m

3

/h

(at high fan speed)
Operating temperature

7 °C to 35 °C

Dimensions width

660 mm

height

750 mm

depth

345 mm

Weight (net)

39 kg

44 kg

Technical data

Technical data

7