ADTRAN HDSL HTU-C/DDM+ User Manual

Htu-c / ddm

Advertising
background image

HTU-C / DDM

JOB

A

ID

61246003L2-22B

0003

HTU-C / DDM+

CLEI: T1L3B5BA_ _

HTU-CM

1246003L2

R
S

2
3
2

STATUS

STATUS LEDs

STATUS

RED

Alarm on any HTU-C loops, HRE loops, DSX or DS1 interface

FLASHING

Signal Quality of 0 or No Sync on at least one loop

YELLOW

Loopbacks active

FLASHING

In-band loopbacks armed

GREEN

Functioning properly

FLASHING

ES, SES, or BPV detected at either DSX or DS1 interface

RS-232 DB-9 CONNECTOR

Used to access the HDSL utilities menu tree via VT100 emulation software such as
terminal, Hyper Terminal – Private Edition and ProComm Plus.

Provision terminal port as follows:

Data Rate — 9.6 kbps, 19.2 kbps
Asynchronous Data Format — eight data bits, no parity (none), one stop bit

Hardware Flow Control should be disabled.

When using a PC with terminal software, be sure to disable any power saving programs.

COMPLIANCE CODES

This product complies with UL 1459, third edition. It is intended to be installed in an
enclosure with an Installation Code (IC) of “B” or “E” and in Restricted Access
Locations only. Input current at maximum load is 0.7 A. Output ratings on the net-
work are maximum 165 mA at -190 Vdc.

WARRANTY

Warranty for Carrier Networks products manufactured by ADTRAN and supplied
under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of
ADTRAN’s U.S. and Canada Carrier Network Equipment Warranty: (877) 457-5007,
Document #414.

HARDWARE SWITCHES

SW1

Rotary switch sets the DSX-1 line build out

0

0 — sets LBO to 0-133 feet

1

133 — sets LBO to 133-266 feet

2

266 — sets LBO to 266-399 feet

3

399 — sets LBO to 399-533 feet

4

533 — sets LBO to 533-655 feet

Note: Positions 5,6 & 7 are not used.

SW2

Is used to provision the card. Default settings are in bold.

SW2-1 — sets the line code to either AMI or B8ZS

SW2-2 — sets the T1 framing to either Unframed or Framed

Note: Unframed operation ignores the setting of SW2-3.

SW2-3 — sets the T1 framing to either SF or ESF

SW2-4 — Enables or disables the NIU loopback option

SW2-5 — Enables or disables the Loopback Timeout option

Default timeout setting is 20 minutes

Must be enable prior to initiating a loopback

SW3

Selects the span powering voltage

LV — selects –140 Vdc to span power a single HTU-R or

one HRE and an HTU-R

HV — selects –190 Vdc to span power two HREs and an

HTU-R

For complete Installation and Maintenance: (877) 457-5007, Document #461. Please have your fax number available.

+

C A U T I O N

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Code

Input Output

Power Code (PC)

F

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

Advertising