Hdsl troubleshooting guide – ADTRAN HDSL HTU-C/DDM+ User Manual

Page 2

Advertising
background image

INDICATIONS AND PROBABLE CAUSES

Front Panel or Circuit Parameters Indicate Abnormal Operation

Connect a terminal emulator via the RS-232 (DB-9) craft interface on faceplate. The terminal
must be VT100 or compatible and set for 1.2 to 19.2 kbps, 8 data bits, no parity, 1 stop bit. Tap
the space bar to establish communication with the unit. Select “M” from the ADTRAN Screen
and “1” from the HDSL main menu. Verify the following conditions on the Current System
Status Screen:

Is signal quality fluctuating (graphical meter indicators bouncing up and down)?

Is LOSS (pulse attenuation) > 30 dB?

Are there any errors counting on the ES, SES, or UAS registers?

If signal quality is NOT fluctuating, is it equal on both loops?

Is the current signal quality indication (uppermost “x” on the meter) more than 1 dB below
the MAX?

Is the current LOSS reading more than 1 dB below the MAX?

If any of these conditions exist, a cable problem is probable and cable testing should be done to
verify all HDSL deployment guidelines are met. These conditions may also reflect intermittent
cable faults or excessive noise impairments. If intermittent faults or noise impairments are
suspected, select “2” from the HDSL main menu and review the Performance History Screen.
If all of the above conditions are met, as well as the HDSL Deployment Guidelines (noted
below), the circuit should provide quality service and can be released.

Front Panel Indications Under Normal Operation:

STATUS

Green

Circuit Parameters Under Normal Operation:

LOSS < 35dB

Signal quality of 6 dB or higher, with no fluctuation and equal on both loops

All HDSL Deployment Guidelines are met

HDSL DEPLOYMENT GUIDELINES

Cable pairs must be non-loaded

Total bridged tap < 2.5 kft

No single bridged tap > 2 kft

196 kHz insertion loss < 35 dB

Pulse attentuation (loss on HDSL current system status screen) 30 dB

Maximum loop resistance is 800

Impulse noises < 50 dBm as measured using a 50 kHz filter and quite termination

Wideband noise

≤ 31 dBm as measured using a 50 kHz filter and quite termination

HDSL TROUBLESHOOTING GUIDE

PRICING AND AVAILABILITY 800.827.0807

TECH SUPPORT 800.726.8663

RETURN FOR REPAIR 256.963.8722

www.adtran.com

61246003L2-22B