Check the wire size.

NOTES:
• Wire Size (Battery Lead, Ground Lead):

Recommended wire size for this unit is AWG4 or larger.

• Wire Size (Remote Turn-on Lead):

Recommended wire size for this unit is AWG8 – AWG14.

• If the wire gauge used is unknown, ask your dealer.

2

Remove the insulation from the ends of the wire leads by about 7 – 10mm (9/32"
– 3/8"). (Fig. 7)

NOTES:
• If length of the exposed wire is too short, a poor connection may occur causing operation

failure or sound interruption.

• On the other hand, if the length is too long, an electrical short-circuit may occur.

Connections

Cautions on wire lead connections

• Use Power Supply wire sold at your dealer’s store.
• Refer to the description below for the proper procedure.

If you are in doubt about how to make this connection, consult your dealer.

Fig. 7

7 – 10 mm (9/32" – 3/8")

Lead end side of the product