CONNECTION/INSTALLATION

Auto white balance control adjustment

Each light source has its own colour temperature. Therefore, when the main light source
lighting an object is changed, the white balance should be adjusted again by pressing the
AWC button.

1.

Place a white object under the same
lighting condition as the object to be shot
and zoom in to fill the screen with white.

2.

When the AWC button is pressed for
approx. one sec., the white balance is
adjusted for the object being recorded.

3.

During the time when the Auto White
function is operated, “AWC OPERA-
TION” is displayed (for approx. 0.5 sec.).
When the appropriate white balance is
acquired, “AWC OK” is displayed.

4.

Error message display
NG : OBJECT

Displayed when there is not enough
white colour on an object or the colour
temperature is not suitable.
By taking a shot of a white object to
fill the screen, adjust the white balance
again.

ERROR : LOW LIGHT

Displayed when the light is low. In-
crease the illumination then re-adjust
the white balance.

ERROR : HIGH LIGHT

Displayed when the light is too bright.
Decrease the illumination then re-ad-
just the white balance.

AWC button

AWC OK

DISPLAYING RESULT

AWC OPERATION

DURING OPERATION

AWC NG : OBJECT

OBJECT ERROR

AWC ERROR : LOW LIGHT

LOW LIGHTING

AWC ERROR : HIGH LIGHT

OVER LIGHTING