English

1. Checking the strength of the

installation location

The ceiling-hanging bracket weighs approximately 16 kg

(35.3 lbs).
Refer to the instruction manual of the plasma display,
and check the weight of the plasma display unit which
will be fitted into the ceiling-hanging bracket.

Refer to the outline drawing of the ceiling-hanging

bracket shown on the right, and check the ceiling
strength at the eight installation positions shown. If the
strength at any of these positions is lacking, provide
sufficient reinforcement.

2. Prepare the ceiling unit

Remove the protective sheets (8 sheets) for the bracket

of the ceiling unit at four locations.

Set a spring washer on the rotation stop screw ,

and fix at the position show on the right.
(Tightening torque: 1.5 to 1.8 N•m)

Remove the two M8 assembly bolts from the ceiling unit

and separate the upper and lower sections of the unit.

• Use the removed M8 assembly bolts when attaching the

ceiling unit (lower section).

Note

• If using a 58-inch plasma display, adjust the attachment

brackets as shown in the figure.

Remove the positioning screws (top and bottom), and

slide the positioning brackets and attachment brackets
as indicated by the arrows.

Align the screw holes, and secure with the removed

screws.
(Adjust the opposite side in the same way.)
(Tightening torque: 1.5 to 2.0 N•m)

3. Install the ceiling unit (upper section)

Before installing the upper section on the ceiling, pass

the wiring through the pipe as shown in the figure on the
right. Use an earthed extension cord for the power cord
(not supplied).
Pass the other device connection cables through the
same way.

Make holes for inserting M12 bolts on the ceiling using

a method appropriate for the ceiling structure. Install
the upper section using a hex socket bolt (M12) (not
supplied), flat washer and spring washer.

* Attach a ceiling cover to the ceiling board if needed

using three truss tapping screws .

Unit: mm (inches)

300 (11.9)

200 (7.9)

300 (11.9)

350 (13.8)

200 (7.9)

24

(1.0)

14

(0.6)

R7

(R0.3)

(Back side

connection part)

Rotation stop

screw 

Spring washer 

Positioning bracket

Positioning bracket

Remove the

positioning

screws.

Secure

removed

positioning

screws here.

View from rear

Ceiling installation holes (8)

Front

Ceiling unit

(upper section)

M8 assembly bolt

Ceiling unit

(lower section)

Flat washer

Spring washer

M12 bolt

Device connection cables

Earthed power extension cord

Ceiling cover 

Truss tapping screw 

Fitting procedure