English, Setting up the special functions, Select functions and set your desired timer – Panasonic LIAC7IM3 User Manual

Page 5: Display function

Advertising
background image

ENGLISH

5

SETTING UP THE SPECIAL FUNCTIONS

SETTING UP THE SPECIAL FUNCTIONS

• After initial installation, you can manually adjust the settings. The initial setting remains active until the user changes it.

• The control panel can be used for multiple installations. Some functions may not be applicable to your unit.

TIMER

OUTDOOR

HEAT

SETTING
STATUS
PUMPDW

BOOSTER

QUIET

TANK

WATER OUTLET

C

C

HEATER

OPERATION

FORCE

HEATER

ACTUAL

MONTUEWEDTHU FRI SAT SUN

REMOTE

ON

Day display

YES / NO / Temperature display

SETTING / STATUS indicator

Functions*

Timer display

SET

SELECT

CANCEL

SETTING

STATUS

SEARCH

CHECK

SELECT FUNCTIONS AND SET YOUR DESIRED TIMER

1. Press

SET

and

CHECK

simultaneously for 5 seconds to enter special setting mode. “SETTING” and “STATUS” indicator is ON.

2. Press or

to browse functions.

3. Press

SELECT

to enter the function.

4. Press or

to enable YES or disable NO function, or set your desired day and time.

5. Press

SET

to confi rm.

Display

Function *

External Thermo Controller (YES / NO)
To set external thermo controller connection.
Tank Connection (YES / NO)
To set tank connection.
Heating Priority (YES / NO)
To choose the heat pump only use for Heating side during HEAT + TANK mode.
Heating Heat-up Interval Set
To set timer for Heating during HEAT + TANK mode (0.5hour ~ 10hours).
Tank Heat-up Interval Set
To set timer for Tank during HEAT + TANK mode (5minutes ~ 1hour 35minutes).
Booster Heater Delay Time Set
To set delay timer for booster heater to ON if tank temperature is not reached (20minutes ~ 1hour 35minutes).
Sterilization (YES / NO)
To set sterilization, if required.
Sterilization Day & Time Set
To set timer for sterilization (only once a week).
Sterilization Temperature Set
To set temperature for sterilization function (40°C ~ 75°C).
Sterilization Continue Time
To set timer to maintain heating temperature in order to complete the sterilization function (5minutes ~ 1hour).

01_F567343_OYTH0912-00_EN.indd 5

01_F567343_OYTH0912-00_EN.indd 5

1/28/2010 9:51:01 AM

1/28/2010 9:51:01 AM

Advertising