1. Disconnect all electrical power to the heater; turn OFF circulating pump.

2. At the two (2) connection unions, disconnect the plumbing to the heater (removal is counter-

clockwise).

3. Locate the hand drain plug at lower, front corner of heater. See Figure-3 (position may vary

between models). Remove plug.

4. Permit all of the water to drain out of the condenser and then replace the plug; thread the plug in

clockwise until just snug, then apply an additional 1/8 turn.

5. To prevent insects and vermin from entering the plumbing during the winterized period, partially

reconnect the two (2) plumbing connection unions: couple each union one or two threads; this
will permit condensation to drain, but will prevent most insects and animals from entering the
plumbing circuit.

6. Next Season: To ready the heat pump for use, simply retighten plumbing connection unions.

Hand-tight is generally sufficient.

Winterizing Procedure:

While the plumbing connections are in the winterized condition (not fully tightened), it is
imperative pool/spa water not be circulated through the heat pump. Loss of water through
loose plumbing connections may result in damage to circulating pump, pool-spa structure,
and/or other equipment.

Failure to heed the following can result in damage to
equipment and/or property.