Continuous usage and water around unit, Required hours of pool pump operation – Aquacal 100 EN User Manual

Page 65

Advertising
background image

11

GETTING YOUR HEAT PUMP STARTED & STOPPED

(Continued)

8. In operation, whenever the actual (displayed) water temperature falls below

the desired set point, the unit will start heating after an initial time delay of
3-4 minutes.

NOTE: T

HE HEAT PUMP INCORPORATES AN ANTI

-

SHORT CYCLE TIME DELAY

. S

HOULD

OPERATION BE INTERRUPTED

,

RESTART WILL BE DELAYED BY APPROXIMATELY

4-

MINUTES

.

CONTINUOUS USAGE AND WATER AROUND UNIT

o If you have followed the directions up to this point, you should be on your way to

enjoying a warm pool or hot spa.

o After the heat pump has been running for some time, you may see water present

around the heater. This water is condensation produced as a by-product of
transferring heat from the air to your pool or spa. If the humidity is high, water
quantities of 6-8 gallons per hour are not uncommon. Conversely, a low-
humidity condition may result in no condensation being produced.

REQUIRED HOURS OF POOL PUMP OPERATION

S

OME POOL SYSTEMS UTILIZE A TIMER TO CONTROL THE POOL FILTER PUMP ON A TIME

-

OF

-

DAY

BASIS

. I

F YOUR POOL SYSTEM INCORPORATES A TIMER

,

USE THE FOLLOWING INSTRUCTIONS

:

o It will be necessary to allow your pool circulator pump to run continuously until

the pool has reached the desired temperature.

o If a timer controls your pump, it will be necessary to override the timer to

temporarily allow for 24-hr. pump operation.

o Once the desired temperature has been obtained (this may take up to four days),

you should reset your pump time clock for normal operating hours.

R

EMEMBER

THE HEAT PUMP CAN ONLY OPERATE WHEN THE CIRCULATOR

P

UMP IS RUNNING

. T

HEREFORE

,

IN ORDER TO KEEP UP WITH INCREASED HEAT

LOSS DURING COOLER WEATHER

,

IT MAY BE NECESSARY TO EXTEND THE PUMP

S

DAILY HOURS OF OPERATION

.

TO SHUT THE UNIT OFF

o The unit can be stopped by switching off the electrical supply or by setting the

desired temperature lower than the actual water temperature.

o The unit will display “OFF” if the desired water temperature is set below 60°F.

Page 5 of 5

Advertising