Logic Controls LK1600 User Manual

Page 24

Advertising
background image

24

LK1600 User Manual Rev. 1

1. Edit the keyboard programming template; or load a template from a file; or read the

template from the keyboard. In the programming utility main menu, click Configuration
on the menu bar and then click on [Edit MR Data]. You can also click the “MR data edit”
icon on the tool bar. The MSR parameter edit dialog box will be displayed.

2. For Prefix, Suffix, and Terminator, following special characters can be inserted with

special formatted string (although there are 4 letters in the string, it will be considered as
one character):

Carriage Return (Enter key) - [CR]
Tab (Tab Key)

- [TB]

IF "[" character is required in the string, enter "[[". For example, "[[T1]" will send out string
"[T1]".

3. Card Data Prefix: maximum 4 characters, sent before card data output.

Card Data Suffix: maximum 4 characters, sent after card data output.

4. Skip output of track with error: do not output any track that was read with an error, other

tracks without error will be sent to computer.
No data output with any error: do not output any data if any track was read with an error.


5. Enable beep at good read: when enabled, keyboard sounds a beep after a good card

read.
Enable 3 beeps at card read error: when enabled, keyboard sounds 3 short beeps after
a card read error.

6. Enable Data: enable track data output for each individual track.

Advertising